POST APPLE SCIENTIFIC INC -- STRONTIUM NITRATE,85900 -- 6810-00D007677
=====================  Product Identification  =====================

Product ID:STRONTIUM NITRATE,85900
MSDS Date:06/01/1994
FSC:6810
NIIN:00D007677
=== Responsible Party ===
Company Name:POST APPLE SCIENTIFIC INC
Address:8893 GULF ROAD
City:NORTH EAST
State:PA
ZIP:16428-4298
Country:US
Info Phone Num:814-725-3330/FAX:814-725-8103
Emergency Phone Num:814-725-3330
CAGE:EO236
=== Contractor Identification ===
Company Name:CHEM SCIENTIFIC INC
Address:1250 WASHINGTON ST
Box:City:NORWOOD
State:MA
ZIP:02062
Country:US
Phone:781-440-0900
Contract Num:MDA414-99-P-4291
CAGE:0X801
Company Name:POST APPLE SCIENTIFIC INC
Address:8893 GULF ROAD
Box:UNKNOW
City:NORTH EAST
State:PA
ZIP:16428-4298
Country:US
Phone:814-725-3330
CAGE:06JC6
Company Name:POST APPLE SCIENTIFIC INC FORMERLY GORDON POST LAB
Address:8893 GULF ROAD
Box:City:NORTH EAST
State:PA
ZIP:16428
Country:US
Phone:814-725-3330 FAX: 814-725-8103
CAGE:EO236

=============  Composition/Information on Ingredients  =============

Ingred Name:STRONTIUM NITRATE
CAS:10042-76-9
RTECS #:WK9800000
Other REC Limits:NONE RECOMMENDED

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:LD50 (ORAL, RAT) 2750 MG/KG

=======================  First Aid Measures  =======================

First Aid:IN CASE OF CONTACT, IMMEDIATELY FLUSH EYES OR SKIN WITH
    COPIOUS AMOUNTS OF WATER FOR AT LEAST 15 MIN WHILE REMOVING
    CONTAMINATED CLOTHING & SHOES. IF INHALED, REMOVE TO FRESH AIR. IF
    NOT BREATHING GIV E ARTIFICIAL RESPIRATION. IF BREATHING IS
    DIFFICULT, GIVE OXYGEN. IF SWALLOWED, WASH OUT MOUTH WITH WATER
    PROVIDED PERSON IS CONSCIOUS. CALL A PHYSICIAN. WASH CONTAMINATED
    CLOTHING BEFORE REUSE.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:WATER SPRAY.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
    PROTECTIVE CLOTHING TO PREVENT CONTACT WITH SKIN AND EYES.
    OXIDIZER.
Unusual Fire/Explosion Hazard:CONTACT WITH OTHER MATERIALS MAY CAUSE
    FIRE. EMITS TOXIC FUMES UNDER FIRE CONDITIONS.

==================  Accidental Release Measures  ==================

Spill Release Procedures:EVACUATE AREA. WEAR SELF-CONTAINED BREATHING
    APPARATUS, RUBBER BOOTS AND HEAVY RUBBER GLOVES. COVER WITH LIME OR
    SODA ASH, PICK UP, KEEP IN A CLOSED CONTAINER AND HOLD FOR WASTE
    DISPOSAL. VENTILATE AR EA AND WASH SPILL SITE AFTER IMMEDIATE
    PICKUP IS COMPLETE.
Neutralizing Agent:DRY LIME OR SODA ASH.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN A COOL, DRY PLACE. KEEP
    TIGHTLY CLOSED. KEEP AWAY FROM COMBUSTIBLE MATERIALS, HEAT, SPARKS,
    AND OPEN FLAME.
Other Precautions:IRRITANT. DO NOT GET IN EYES, ON SKIN,  ON CLOTHING.
    AVOID BREATHING DUST.  USE ONLY IN A CHEMICAL FUME HOOD. AVOID
    PROLONGED OR REPEATED EXPOSURE.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:WEAR APPROPIATE NIOSH/MSHA-APPROVED RESPIRATOR.
Ventilation:USE ONLY IN A CHEMICAL FUME HOOD.
Protective Gloves:WEAR CHEMICAL-RESISTANT GLOVES.
Eye Protection:WEAR SAFETY GOGGLES.
Other Protective Equipment:WEAR APPROPIATE NIOSH/MSHA-APPROVED
    RESPIRATOR, CHEMICAL-RESISTANT GLOVES, SAFETY GOGGLES, OTHER
    PROTECTIVE CLOTHING. SAFETY SHOWER AND EYE BATH.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING. WASH
    CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
CHEMICAL SCIENTIFIC: STRONTIUM NITRATE / PART# S281 - 500 G. OXIDIZER.

==================  Physical/Chemical Properties  ==================

HCC:D1
Melt/Freeze Pt:=570.C, ######F
Spec Gravity:2.990
Appearance and Odor:WHITE CRYSTALS AND CHUNKS.

=================  Stability and Reactivity Data  =================

STRONG ACIDS, STRONG REDUCING AGENTS.
Hazardous Decomposition Products:NITROGEN OXIDES.

===================  Toxicological Information	===================

Toxicological Information:TO THE BEST OF OUR KNOWLEDGE, THE CHEMICAL,
    PHYSICAL, & TOXICOLOGICAL PROPERTIES HAVE NOT BEEN THOROUGHLY
    INVESTIGATED. RTECS NO: WK9800000. STRONTIUM (II) NITRATE (1:2).
    TOXICITY DATA: ORL-RAT LD50:2 750 MG/KG, IPR-RAT LD50: 540MG/KG,
    ORL-MUS LD50: 1826 MG/KG, ORL-RBT LD50: 3865 MG/KG, ORL-GPG LD50:
    7432 MG/KG, ORL-MAM LD50:> 15000 MG/KG. ONLY SELECTED REGISTRY OF
    TOXIC EFFECTS OF CHEMICAL SUBSTAN CES (RTECS) DATA IS PRESENTED
    HERE. SEE ACTUAL NTRY IN RTECS FOR COMPLETE INFORMATION.

=====================  Ecological Information  =====================

Ecological:DATA NOT YET AVAILABLE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:TO A SOULTION OF THE PRODUCT IN WATER, ADD AN
    EXCESS OF DILUTE SULFURIC ACID. LET STAND OVERNIGHT. REMOVE ANY
    INSOLUBLE AND BURY IN A LANDFILL SITE APPROVED FOR HAZARDOUS WASTE
    DISPOSAL. OBSERVE ALL F EDERAL, STATE AND LOCAL ENVIRONMENTAL
    REGULATIONS.

===================  MSDS Transport Information  ===================

Transport Information:CONTACT CHEMICAL COMPANY FOR TRANSPORTATION
    INFORMATION.

=====================  Regulatory Information  =====================

Federal Regulatory Information:NOHS 1974: HZD 84461; NIS 2; TNF 19; NOS
    2; TNE 363. NOES 1983: HZD 84461; NIS 4; TNF 124; NOS 5; TNE 2667;
    TFE 1895. EPA TSCA CHEMICAL INVENTORY, JANUARY 1993.

=======================  Other Information  =======================

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.