C R C CHEMICALS -- DISC BRAKE QUIET 5016 -- 6850-00N035466
===================== Product Identification =====================
Product ID:DISC BRAKE QUIET 5016
MSDS Date:11/01/1985
FSC:6850
NIIN:00N035466
=== Responsible Party ===
Company Name:C R C CHEMICALS
Address:885 LOUIS DR
City:WARMINSTER
State:PA
ZIP:18974
Country:US
Info Phone Num:215-674-4300
Emergency Phone Num:215-674-4300
Preparer's Name:A.B. REED
CAGE:IO004
=== Contractor Identification ===
Company Name:C R C CHEMICALS
Address:885 LOUIS DR
City:WARMINSTER
State:PA
ZIP:18974
Country:US
Phone:215-674-4300
CAGE:IO004
Company Name:CRC INDUSTRIES, INC.
Address:885 LOUIS DRIVE
Box:City:WARMINSTER
State:PA
ZIP:18974-2820
Country:US
Phone:215-674-4300/800-424-9300
CAGE:10136
============= Composition/Information on Ingredients =============
Ingred Name:ETHYLENE GLYCOL (SARA III)
CAS:107-21-1
RTECS #:KW2975000
Fraction by Wt: 2%
OSHA PEL:50 PPM,C
ACGIH TLV:50 PPM,C
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB
Ingred Name:PIGMENTS
Fraction by Wt: <1%
Ingred Name:WATER
CAS:7732-18-5
RTECS #:ZC0110000
Fraction by Wt: 40%
Ingred Name:ACRYLIC ACID, POLYMERS (ACRYLIC POLYMER)
CAS:9003-01-4
RTECS #:AT4680000
Fraction by Wt: 57%
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:SKIN:CAN CAUSE MILD TRANSIENT
RASH ON PROLONGED EXPOSURE. EYE:MILDLY IRRITATING. CHRONIC:NOT
APPLICABLE.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NOT APPLICABLE.
======================= First Aid Measures =======================
First Aid:INHAL:MOVE TO FRESH AIR. EYE:WASH THOROUGHLY WITH LARGE
AMOUNTS OF WATER. SKIN:WASH AND RINSE THOROUGHLY. INGEST:INDUCE
VOMITING AND CALL MD.
===================== Fire Fighting Measures =====================
Flash Point:NONE
Extinguishing Media:USE MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.
================== Accidental Release Measures ==================
Spill Release Procedures:MATERIAL DOES NOT FLOW AND WOULD BE DIFFICULT
TO SPILL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN A COOL DRY AREA.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NOT NORMALLY REQUIRED. NIOSH/MSHA APPROVED
RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:NOT NORMALLY REQUIRED.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NOT NORMALLY REQUIRED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
================== Physical/Chemical Properties ==================
HCC:N1
Boiling Pt:B.P. Text:212F,100C
Melt/Freeze Pt:M.P/F.P Text:32.0F,0.0C
Spec Gravity:1.0487
Solubility in Water:MAY BE DISPURSED
Appearance and Odor:RED PASTE W/ACRYLIC ODOR
Percent Volatiles by Volume:40
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:DRIED FILM WOULD BURN GIVING OFF
CARBON DIOXIDE AND CARBON MONOXIDE.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE IN ACCORDANCE TO FEDERAL, STATE AND
LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.