MALLINCKRODT BAKER INC -- POLYETHYLENE GLYCOL, 7755 -- -
===================== Product Identification ===================== Product ID:POLYETHYLENE GLYCOL, 7755 MSDS Date:12/08/1996 FSC:NIIN:Submitter:N EN Status Code:A === Responsible Party === Company Name:MALLINCKRODT BAKER INC Address:222 RED SCHOOL LANE City:PHILLIPSBURG State:NJ ZIP:08865 Country:US Info Phone Num:800-582-2537 Emergency Phone Num:908-859-2151 Resp. Party Other MSDS Num.:P5029 Chemtrec Ind/Phone:(800)424-9300 CAGE:70829 === Contractor Identification === Company Name:MALLINCKRODT BAKER, INC. Address:222 RED SCHOOL LANE Box:City:PHILLIPSBURG State:NJ ZIP:08865 Country:US Phone:800-582-2537 CAGE:70829 ============= Composition/Information on Ingredients ============= Ingred Name:POLYETHYLENE GLYCOL. WEEL: 10 MG/M3, 8-HOUR, TWA (M). CAS:25322-68-3 RTECS #:TQ3500000 Minumum % Wt:90. Maxumum % Wt:100. ===================== Hazards Identification ===================== LD50 LC50 Mixture:SEE TOXICOLOGICAL INFORMATION. Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:ACUTE: INHALATION: NO ADVERSE HEALTH EFFECTS EXPECTED FROM INHALATION. (MAY BE A MECHANICAL IRRITANT). INGESTION: LARGE DOSES OF THE LOWER MOLECULAR WEIGHT PRODUCTS MAY CAUSE GASTRO-INTESTINAL UPSET. SKIN CONTACT: NO ADVERSE EFFECTS EXPECTED. EYE CONTACT: NO ADVERSE EFFECTS EXPECTED. CHRONIC: NO INFORMATION FOUND. Effects of Overexposure:SEE HEALTH HAZARDS. Medical Cond Aggravated by Exposure:DAMAGED SKIN. ======================= First Aid Measures ======================= First Aid:INHALATION: REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE O*2/ARTF RESP) . INGESTION: IF LARGE AMOUNTS WERE SWALLOWED, GIVE WATER TO DRINK AND GET MEDICAL ADVICE. SKIN: IMMEDIATELY FLUSH WITH PLE NTY OF SOAP AND WATER FOR AT LEAST 15 MINUTES. REMOVE CONTAMINATED CLOTHING AND SHOES. WASH CLOTHING BEFORE REUSE. GET MEDICAL ATTENTION IF IRRITATION DEVELOPS OR PERSISTS. EYES: FLUSH WITH PLENTY OF WATER FOR AT LEAST 15 MINUTES. GET MEDICAL ADVICE IF IRRITATION DEVELOPS. ===================== Fire Fighting Measures ===================== Flash Point:>182.C, 359.6F 182-287C Extinguishing Media:WATER SPRAY, DRY CHEMCIAL, ALCOHOL FOAM, OR CARBON DIOXIDE. Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE EQUIPMENT . Unusual Fire/Explosion Hazard:FIRE: AS WITH MOST ORGANIC SOLIDS, FIRE IS POSSIBLE AT ELEVATED TEMPS OR BY CONTACT WITH IGNITION SOURCE. (INCREASES AS MOLECULAR WEIGHT INCREASES). EXPLO: FINE DUST DISPERSED IN AIR IN SUFFICIENT CON CS, & IN PRESENCE OF IGNIT SOURCE IS POTNTL DUST EXPLO HAZ. NFPA RATINGS: HEALTH - 0; FLAMMABILITY - 1; REACTIVITY - 0. ================== Accidental Release Measures ================== Spill Release Procedures:REMOVE ALL SOURCES OF IGNIT. VENT AREA OF LEAK/SPILL. WEAR APPROP PPE AS SPECIFIED IN THIS MSDS. SOLID SPILLS: CLEAN UP SPILLS IN A MANNER THAT DOES NOT DISPERSE DUST INTO AIR. USE NON-SPARKING TOOLS & EQUIP. REDUCE AIRBORNE DUST & PVNT SCATTERING BY MOISTENING W/WATER. PICK UP SPILL FOR RECOVERY/DISP & PLACE IN CLSD CNTNR. LIQ SPILLS: ABSORB W/VERMICULITE, DRY SAND, EARTH/SIMILAR MATL & (SUPDAT) ====================== Handling and Storage ====================== Handling and Storage Precautions:STORAGE COLOR CODE: ORANGE (GENERAL STORAGE). KEEP IN A TIGHTLY CLOSED CONTAINER, STORED IN A COOL, DRY, VENTILATED AREA. PROTECT AGAINST PHYSICAL DAMAGE. Other Precautions:CONTAINERS OF THIS MATERIAL MAY BE HAZARDOUS WHEN EMPTY SINCE THEY RETAIN PRODUCT RESIDUES (DUST, SOLIDS, VAPORS, LIQUID); OBSERVE ALL WARNINGS AND PRECAUTIONS LISTED FOR THIS PRODUCT. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:FOR USE W/SOLIDS (NOT REQD FOR LIQS): IF EXPOS LIM IS EXCEEDED, A NIOSH APPRVD HALF-FACE RESP WITH DUST/MIST RESP MAY BE WORN FOR UP TO 10 TIMES EXPOS LIM/MAX USE CONC SPECIFIED BY APPROP REGULATORY A GENCY/RESP SUPPLIER, WHICHEVER IS LOWEST. A NIOSH APPRVD FULL-FACE PIECE DUST/MIST RESP MAY BE WORN UP TO 50 TIMES EXPOS LIM/MAX USE CONC SPECIFIED (OTHER INFO) Ventilation:SYS OF LOC &/OR GEN EXHST IS REC TO KEEP EMPLOYEE EXPOS BELOW AIRBORNE EXPOS LIMS. LOC EXHST VENT IS GENRLY PREF BECAUSE IT CAN CONTROL EMISSIONS OF(SUPP DATA) Protective Gloves:IMPERVIOUS GLOVES . Eye Protection:ANSI APPROVED CHEMICAL WORKERS GOGGLES . Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER . WEAR CLEAN BODY-COVERING CLOTHING, INCLUDING LAB COAT. Work Hygienic Practices:AS PART OF GOOD INDUSTRIAL AND PERSONAL HYGIENE AND SAFETY PROCEDURE, AVOID ALL UNNECESSARY EXPOSURE TO CHEMICAL SUBSTANCE AND ENSURE PROMPT REMOVAL FROM SKIN, EYES AND CLOTHING. Supplemental Safety and Health SPILL PROC:PLACE IN CHEM WASTE CNTNR. DO NOT USE COMBUST MATLS, SUCH AS SAW DUST. DO NOT FLUSH TO SEWER. -- VENT:CONTAM AT ITS SOURCE, PREVENTING DISPERSION OF IT INTO GEN WORK AREA. PLEASE REFER TO A CGIH DOCUMENT, "INDUS VENT, A MANUAL OF REC PRACTICES," MOST RECENT EDITION, FOR DETAILS. ================== Physical/Chemical Properties ================== Boiling Pt:B.P. Text:NO INFORMATION FOUND Melt/Freeze Pt:M.P/F.P Text:SEE OTHER INFO Vapor Pres:SEE OTHER INFO Vapor Density:NO INFO Spec Gravity:2.2-2.3 (SEE OTHER INFO) pH:NO INFO FOUND Evaporation Rate & Reference:NO INFORMATION FOUND Solubility in Water:SOLUBLE Appearance and Odor:CLEAR LIQUID OR WHITE SOLID; MILD ODOR. Percent Volatiles by Volume:NO INFO ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES INCOMPATIBLE WITH POLYMERIZATION CATALYSTS (PEROXIDES, PERSULFATES) AND ACCELERATORS, STRONG OXIDIZERS, STRONG BASES AND STRONG ACIDS. Stability Condition to Avoid:INCOMPATIBLE. STABLE UNDER ORDINARY CONDITIONS OF USE AND STORAGE. Hazardous Decomposition Products:CARBON DIOXIDE AND CARBON MONOXIDE MAY FORM WHEN HEATED TO DECOMPOSITION. Conditions to Avoid Polymerization:WILL NOT OCCUR. =================== Toxicological Information =================== Toxicological Information:PEG - LD50:(ORAL,RAT) 28 GM/KG (FOR 200); LD50:(ORAL,RAT) 27.5 GM/KG (FOR 300); LD50:(ORAL,RAT) 30.2 GM/KG (FOR 400); LD50:(ORAL,RAT) 30 GM/KG (FOR 600); LD50:(ORAL,RAT) 32 GM/KG (FOR 1000); LD50:(ORA L,RAT) >4 GM/KG (FOR 1450); LD50:(ORAL,RAT) 50 GM/KG (FOR 4000); LD50:(ORAL,RAT) >50 GM/KG (FOR 6000); LD50:(ORAL,RAT) 31.6 MG/KG (FOR 20,000). POLYETHYLENE GLYCOL HAS BEEN INVESTIGATED AS A MUTAGEN, PEG 1000 HAS BEEN INVESTIGATED AS A TUMORIGEN. ===================== Ecological Information ===================== Ecological:ENVIRONMENTAL FATE AND TOXICITY: NO INFORMATION FOUND. ==================== Disposal Considerations ==================== Waste Disposal Methods:WHATEVER CANNOT BE SAVED FOR RECOVERY OR RECYCLING SHOULD BE MANAGED IN APPROPRIATE & APPROVED WASTE DISPOSAL FACILITY. PROCESSING, USE OR CONTAMINATION OF THIS PRODUCT MAY CHANGE WASTE MANAGEMENT OPT IONS. STATE & LOCAL DISPOSAL REGULATIONS MAY DIFFER FROM FED DISPOSAL REGS. DISPOSE OF CNTNR & UNUSE D CONTENTS I/A/W FED, STATE & LOCAL REQUIREMENTS. =================== MSDS Transport Information =================== Transport Information:NOT REGULATED. ===================== Regulatory Information ===================== SARA Title III Information:POLYETHYLENE GLYCOL - CAS #25322-68-3: SARA 302: RQ & TPQ - NO; SARA 313: LIST & CHEMICAL CATEGORY - NO. CERCLA: NO. SARA 311/312: ACUTE - NO; CHRONIC - NO; FIRE - NO; PRESSURE - NO. REACTIVITY - NO. (PURE/SOLID). Federal Regulatory Information:POLYETHYLENE GLYCOL - CAS # 25322-68-3: TSCA & JAPAN - YES; EC & AUSTRALIA - NO; KOREA, DSL - YES; NDSL - NO; PHIL - YES. RCRA 261.33 - NO. TSCA 8 (D) - NO. CHEMICAL WEAPONS CONVENTION: NO; TSCA 12 (B ): NO; CDTA; NO. AUSTRALIAN HAZCHEM CODE: NO INFORMATION FOUND. POISON SCHEDULE: NO INFORMATION FOUND. WHMIS: THIS MSDS HAS BEEN PREPARED ACCORDING TO HAZARD CRITERIA OF CONTROLLED PRODUCTS REGS (CPR) & MSDS CONTAINS ALL OF THE INFORMATION REQUIRED BY CPR. ======================= Other Information ======================= Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.