MOBIL OIL CORP -- VACUUM PUMP OIL -- 9150-00-273-8664
=====================  Product Identification  =====================

Product ID:VACUUM PUMP OIL
MSDS Date:01/01/1995
FSC:9150
NIIN:00-273-8664
=== Responsible Party ===
Company Name:MOBIL OIL CORP
Address:3225 GALLOWS RD
City:FAIRFAX
State:VA
ZIP:22037
Country:US
Info Phone Num:800-662-4525/703-849-3265
Emergency Phone Num:609-737-4411/800-424-9300(CHEMTREC)
CAGE:6G112
=== Contractor Identification ===
Company Name:MOBIL OIL CORP
Address:3225 GALLOWS RD
Box:City:FAIRFAX
State:VA
ZIP:22037
Country:US
Phone:800-662-4525, 856-224-4644
CAGE:6G112

=============  Composition/Information on Ingredients  =============

Ingred Name:NON-HAZARDOUS INGREDIENTS
Fraction by Wt: 100%
Other REC Limits:NONE RECOMMENDED

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:LD50(ORAL,RAT) >2,000 MG/KG;TLV 5 MG/M3.
Routes of Entry: Inhalation:NO	Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:TARGET ORGANS:NONE. ACUTE-
    ORAL:PRACTICALLY NON-TOXIC. INHALATION:UNLIKELY FOR HANDLING, USE,
    MISUSE OF THIS PRODUCT. EYE/SKIN:PRACTICALLY NON-IRRITATING.
    CHRONIC- NO ADVERSE EFFECTS.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:NONE
Medical Cond Aggravated by Exposure:NONE

=======================  First Aid Measures  =======================

First Aid:GET MEDICAL HELP IF SYMPTOMS PERSIST. INHALED:NOT EXPECTED TO
    BE A PROBLEM. EYES:FLUSH THROUGHLY WITH WATER. SKIN:WIPE OFF
    EXCESS. WASH SKIN WITH SOAP & WATER. ORAL:NOT EXPECTED TO BE A
    PROBLEM. IF UN COMFORTABLE, SEEK MEDICAL ATTENTION.

=====================  Fire Fighting Measures  =====================

Flash Point Method:COC
Flash Point:>400F,>204C
Extinguishing Media:WATER FOG/SPRAY, CARBON DIOXIDE, FOAM/DRY CHEMICAL.
    DIRECTLY SPRAYING WATER/FOAM ONTO BURNING OIL MAY CAUSE FROTHING.
Fire Fighting Procedures:WEAR FIRE FIGHTING PROTECTIVE EQUIPMENT AND
    NIOSH-APPROVED SELF CONTAINED BREATHING APPARATUS. COOL FIRE
    EXPOSED CONTAINERS WITH WATER SPRAY.
Unusual Fire/Explosion Hazard:CONTAINER MAY BURST.

==================  Accidental Release Measures  ==================

Spill Release Procedures:RECOVER FREE OIL IF POSSIBLE. ABSORB SPILL
    WITH INERT MATERIAL SUCH AS SAND, DIATOMACEOUS EARTH. TRANSFER TO A
    SUITABLE CONTAINER FOR DISPOSAL. PREVENT RUN-OFF TO ENTER
    WATERWAYS, SEWERS. REPORT SPILL  AS REQUIRED TO COAST GUARD
    800-424-8802.
Neutralizing Agent:NOT RELEVANT

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE AWAY FROM EXTREME HEAT & STRONG
    OXIDANTS. KEEP CONTAINERS CLOSED WHEN NOT IN USE. KEEP OUT OF REACH
    OF CHILDREN.
Other Precautions:DO NOT GET IN EYES, ON SKIN OR ON CLOTHING. WASH
    THOROUGHLY AFTER HANDLING. AVOID BREATHING OIL MIST. DISCARD
    LUBRICANT-SOAKED SHOES. REMOVE LUBRICANT-SOAKED CLOTHING AND
    LAUNDER BEFORE RE-USE.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE NORMALLY REQUIRED. IF EXPOSURE MAY OR DOES
    EXCEED OCCUPATIONAL EXPOSURE LIMITS, WEAR A NIOSH-APPROVED ORGANIC
    VAPOR RESPIRATOR.
Ventilation:USE ADEQUATE VENTILATION TO KEEP OIL MISTS OF THIS MATERIAL
    BELOW APPLICABLE STANDARD(S).
Protective Gloves:NITRILE OR NEOPRENE RECOMMENDED
Eye Protection:SAFETY GLASSES, FACE SHIELD RECOMMENDED
Other Protective Equipment:EYE WASH STATION AND SAFETY SHOWER.
    INDUSTRIAL-TYPE WORK CLOTHING AND APRON AS REQUIRED.
Work Hygienic Practices:OBSERVE GOOD PERSONAL HYGIENE PRACTICES AND
    RECOMMENDED PROCEDURES.
Supplemental Safety and Health

==================  Physical/Chemical Properties  ==================

HCC:V6
NRC/State Lic Num:NOT RELEVANT
Boiling Pt:B.P. Text:>600F,>316C
Vapor Pres:<0.1 @ 68F
Vapor Density:>2
Spec Gravity:0.88
Viscosity:67 CST @ 104F
Solubility in Water:NEGLIGIBLE
Appearance and Odor:AMBER LIQUID - MILD ODOR

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS
Stability Condition to Avoid:EXCESSIVE HEAT
Hazardous Decomposition Products:MAY PRODUCE FUMES, SMOKE, CARBON
    MONOXIDE, CARBON DIOXIDE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF WASTE IN COMPLIANCE WITH ALL
    APPLICABLE LOCAL, STATE AND FEDERAL LAWS AND REGULATIONS. RCRA
    EMERGENCY NUMBER: 800-424-9346. DO NOT CONTAMINATE ANY LAKES,
    STREAMS, PONDS OR UNDERGROUND WATER  SUPPLY. INCINERATION IS
    RECOMMENDED.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.